Plantas de SX para Laboratorio

 

 

                                                                                                                                           EnglishEspañol

INICIO

MAPA DEL SITIO

PRODUCTOS

PLANTAS DE SX

PLANTAS DE EW

LIXIVIACIÓN

HIDROMET

COALESCEDORES

SERVICIOS

PROYECTOS

TECNOLOGÍA

FOLLETOS

CONTACTO

 

 

 

     We provide mini solvent extraction pilot plants for laboratory and bench scale solvent extraction test programs. The following summarizes our laboratory scale solvent extraction pilot plants that we recently manufactured for various clients:

      Our Laboratory Solvent Extraction Pilot Plant Features:

  • Completely assembled pilot plant with borosilicate glass mixer-settlers by SX Kinetics

  • Adjustable borosilicate aqueous over-flow weirs for interface level control

  • Variable speed and constant torque mixers, 100 to 240 volts, 50 or 60 Hz

  • SX impellers manufactured from either polypropylene, PVC , or stainless steel

  • Slide-on tubing adaptors for connection of flexible tubing to borosilicate glass tubing

  • Configure for any circuit design including aqueous or organic recycle with flow control valves

  • Galvanize metal support frame with adsorption clamps for borosilicate glass vessels

  • Complete with all accessory fittings, tubing, and operating manual

 

 Para más detalles: Planta SX de Laboratorio 1

Cliente:  Canmine Corporation
Ubicación del sitio: Cobalt, ON, Canada
Capacidad de la Planta: 150 mL/min (org + aq)

SX Kinetics diseñó y fabricó esta planta piloto a escala de banco para un programa de prueba para la extracción por solvente de cobalto. Se le entregó al cliente previamente ensamblada. SX Kinetics suministró asesoría técnica in situ.

     
 

Laboratory or bench scale solvent extraction pilot plant with 4 mixer-settlers.

Para más detalles: Planta SX de Laboratorio 2

Cliente: NJIT
Ubicación del sitio: Newark, NJ, USA
Capacidad de la Planta: 150 m L/min (org + aq) 

Esta planta piloto de extracción por solvente a escala de banco fue diseñada y fabricada por SX Kinetics y enviada al Instituto de Tecnología de New Jersey. Allí fue usada para un programa de investigación sobre la extracción a contracorriente continua de proteínas.

     
 

Laboratory or bench scale solvent extraction pilot plant with 6 mixer-settlers.

Para más detalles: Planta SX de Laboratorio 3

Cliente: Heraeus Metal Processing, Inc
Ubicación del sitio: Santa Fe Springs, CA, USA
Capacidad de la Planta: 150 m L/min (org + aq)

Esta planta piloto de extracción por solvente a escala de banco fue diseñada y fabricada por SX Kinetics, Inc y enviada a California, E.E.U.U.. Allí fue usada para un programa de investigación sobre la extracción a contracorriente continua de metales preciosos.

     
 

Laboratory or bench scale solvent extraction pilot plant with 5 mixer-settlers.

Para más detalles: Planta SX de Laboratorio 4

Cliente: Moscow State Institute of Steel and Alloys (Universidad Tecnológica)
Ubicación del sitio: Moscú, Rusia
Capacidad de la Planta: 150 m L/min (org + aq)

Esta planta piloto de extracción por solvente a escala de banco fue diseñada y fabricada por SX Kinetics, Inc y enviada a Moscú, Rusia. Allí fue usada para un programa de investigación sobre la extracción a contracorriente continua de cobre.

     
 

Laboratory bench scale solvent extraction and electrowinning pilot plant.

Para más detalles: Planta SX de Laboratorio 5

Cliente:  Erdenet Mining Corporation
Ubicación del sitio:  Erdenet, Mongolia
Capacidad de la Planta: 150 mL/min (org + aq)

SX Kinetics diseñó y fabricó esta planta piloto a escala de banco para un programa de prueba para la extracción por solvente de cobre en Mongolia.

Incluyo 6 mezcladores-sedimentadores y fue acoplada a una planta piloto de electro obtención. Detalles de la planta de electro obtención se muestran en:

Planta Piloto de EW 3

     
 

Laboratory leaching, solvent extraction, and electrowinning pilot plant.

Para más detalles: Planta SX de Laboratorio 6

Cliente: Moscow State Institute of Steel and Alloys (Universidad Tecnológica)
Ubicación del sitio: Moscú, Rusia
Capacidad de la Planta: 150 mL/min (org + aq)

SX Kinetics diseñó y fabricó esta planta piloto a escala de banco que incluyó una planta piloto de lixiviación,  extracción por solvente y electroobtención para programas de pruebas en la Universidad Tecnológica en Rusia.

     
 

Laboratory scale solvent extraction pilot plant with 10 stages.

Para más detalles: Planta SX de Laboratorio 7

Cliente: National Iranian Copper Industries
Ubicación del sitio: Tehran, Irán
Capacidad de la Planta: 150 m L/min (org + aq)

Esta planta piloto de extracción por solvente a escala de banco fue diseñada y fabricada por SX Kinetics  y enviada a Irán. Allí fue usada para un programa de investigación sobre la extracción a contracorriente continua de cobre y zinc.

     
 

Bench scale solvent extraction pilot plant.

Para más detalles: Planta SX de Laboratorio 8

Client: Immanuel Technological Solutions
Location: Mississauga, ON, Canada
Plant Capacity: 180 g Zinc per hour

This laboratory solvent extraction and electrowinning pilot plant was designed and manufactured by SX Kinetics for a project to recover zinc from EAF (electric arc furnace) dust.

     
 

Laboratory solvent extraction pilot plant with 15 mixer-settlers.

Para más detalles: Planta SX de Laboratorio 9

Client: Norilsk Nickel Harjavalta Oy
Location: Harjavalta, Finland
Plant Capacity: 150 m L/min (org + aq)

This laboratory solvent extraction pilot plant was shipped pre -assembled to a cobalt refinery in Finland for a cobalt solvent extraction. The solvent extraction pilot plant included 15 mixer-settlers that can be configured for various numbers of extraction, scrubbing, and stripping stages. The plant included metering pumps and 15 immersion heaters.

     
 

Laboratory solvent extraction pilot plant with 10 stages.

Para más detalles: Planta SX de Laboratorio 10

Client: ZeaChem Inc.
Location: Menlo Park, California, USA
Plant Capacity: 150 m L/min (org + aq)

SX Kinetics designed and manufactured this laboratory solvent extraction pilot plant for the purification of acetic acid by new proprietary technology. The laboratory plant featured flanged mixer-settlers with flanged covers in order to provide an air tight seal for use with solvents having a low flash point.

     
 

Laboratory solvent extraction pilot plant for uranium SX investigations.

Para más detalles: Planta SX de Laboratorio 11

Client: Gulf Chemical & Metallurgical Corp.
Location: Freeport, Texas, USA
Plant Capacity: 150 m L/min (org + aq)

This laboratory pilot plant was shipped to a uranium mining plant for a test program aimed at the extraction of uranium from phosphoric acid solutions.

     
 

Laboratory solvent extraction pilot plant with 18 mixer-settlers.

Para más detalles: Planta SX de Laboratorio 12

Client: PCS Phosphate
Location: Aurora, North Carolina, USA
Plant Capacity: 150 m L/min (org + aq)

This laboratory solvent extraction pilot plant featured flanged mixer-settlers with flanged covers in order to provide an air tight seal for use with a solvent at a low flash point. The settlers and organic vessel featured glass jackets for circulation of hot water for operation at elevated temperatures. The pilot plant was used to evaluate the extraction of impurities from phosphoric acid.

     
 

Laboratory solvent extraction pilot plant with 10 mixer-settlers.

Para más detalles: Planta SX de Laboratorio 13

Client: Hellenic Copper Mines Limited
Location: Nicosia, Cyprus
Plant Capacity: 150 m L/min (org + aq)

SX Kinetics designed and manufactured this laboratory solvent extraction pilot for a copper mining company in Cyprus. The plant included 10 stages that can be configured for either organic or aqueous recycle.

     
 

Laboratory solvent extraction pilot plant with two mixer-settlers.

Para más detalles: Planta SX de Laboratorio 14

Client: Biomed International Medical & Scientific Supplies
Location: Surra, Kuwait
Plant Capacity: 150 m L/min (org + aq)

SX Kinetics designed and manufactured this laboratory solvent extraction pilot plant with pH controllers for a research project in Kuwait.

     
 

Laboratory solvent extraction pilot plant for uranium stripping.

Para más detalles: Planta SX de Laboratorio 15

Client: Areva Resources Canada Inc.
Location: McClean Lake, SK, Canada
Plant Capacity: 150 m L/min (org + aq)

SX Kinetics designed and manufactured this laboratory solvent extraction pilot plant with pH controllers for a test program to evaluate various uranium stripping parameters. 

     

 

| INICIO | MAPA DEL SITIO | PRODUCTOS | PLANTAS DE SX | PLANTAS DE EW | LIXIVIACIÓN | HIDROMET | COALESCEDORES | SERVICIOS | PROYECTOS |

TECNOLOGIA | FOLLETOS | CONTACTO |

 

This page was last updated on 12/06/10.

249 Ruttan Terrace, Suite 504, Cobourg, Ontario, Canada, K9A 5X6  Tel: +1 905 372 5981   Fax: +1 905 372 4091

© Copyright 2002 -2010  SX Kinetics, Inc. All Rights Reserved                                               email: steven.webster@sxkinetics.com